Sensors That Make Buildings Smart!
 
Accessories
Air Velocity Measurement Basics
   

Contact Us
Call us to order or for applications assistance.
888-855-8880
Monday to Friday
8:00 AM to 5:00 PM, PST
 
Ways to Pay
We accept orders through our website or by phone.

 
Next Day Delivery
Orders must be received by 1:00 pm PST during business hours.




Mailing List
You can subscribe or unsubscribe to our Mailing List at any time.

0-4,000 fpm

0-4,000 fpm

0-4,000 fpm

0-4,000 fpm
Models EE65-A, EE65-B and EE65-C
Air Velocity Transmitter 0-4,000 fpm

Applications

  • HVAC flow monitoring
  • processing & environmental control
  • clean room control

 

Key Features

  • heated thin-film anemometer
  • low profile of sensing element resists dirt loading (0.15 mm profile)
  • NEMA4/IP65 enclosed (without display)
  • durability, long life and stability proven in demanding automotive applications
  • Now also available with LonWorks® communication capability as a LonMark® Certified product.

 

Options

  • versions for duct, wall or remote probe
  • display option available
  • probe available in 4", 8" and custom lengths
  • variety of cable length available for remote probe

Model EE65

Air Velocity Transmitter

  • Air Velocity Range: 0-4,000 fpm (0-2.0 m/s)
  • Jumper selectable ranges:0-2,000 fpm, 0-3,000 fpm, 0-4,000 fpm (10, 15, 20 m/s)
  • Typical Accuracy @ 20°C: ± 50 fpm + 3% of measurement (see datasheet)
  • Output: 0-10 V, 4-20 mA
  • Response Time T90:Jumper selectable 2 or 0.2 seconds
  • Operating Temperature (probe): -22 to 122°F (-25 to 50°C)
  • Power Requirement: 24 VDC/AC ±10%
  • Max Current Consumption: 150 mA DC, 90mA
  • Angular Dependence: < 3% at 10% angle

Datasheet
Manual
E+E Configuration Software

 

Models

  • EE65-A: Wall Mount
  • EE65-B: Duct Mount
  • EE65-B: Duct Mount with Display
  • EE65-C: Remove Probe

 

 

 

Applications

  • The EE575 is a compact air velocity transmitter designed for high volume applications.
  • The alignment strip along the probe's tube and the matching mounting flange determine the orientation of the sensor probe.
  • The mounting flange allows for an infinitely variation of the depth of the sensor probe.
  • The electronics integrated in the probe tube provide a linear analogue signal of 0-5V or 0-10V for the velocity range 0...5m/s (0...1000ft/min) / 0...10m/s (0...2000ft/min) or 0...20m/s (0...4000ft/min).
  • Response Time: t90: typ. 4 sec (at 10m/s (2000ft/min))
  • Accuracy:
    • 0.5... 5m/s (100...1000ft/min): (0.2m/s / 40ft/min +3% of MV)
    • 1... 10m/s (200...2000ft/min): (0.3m/s / 60ft/min +4% of MV)
    • 1... 20m/s (200...4000ft/min): (0.4m/s / 80ft/min +6% of MV)
  • Power: 10...19 VDC, 19...29VDC

Model EE575

Miniature Airflow Probe
(0-400 FPM) Analog Output


Datasheet
Manual
 
 
Published: February 16, 2004 Last Updated: May 21, 2013